IJTSRD, Partial Replacement of Natural Sand by Microfines for Cement Concrete, by Bharath V B. International Journal of Trend in Scientific Research and Development. Best International Journal, Open Access Journal ISSN: 2456-6470, Impact Factor ...
In the present study manufactured sand with varying proportions from 0 to 40 % by its weight are mixed with concrete materials as a partial replacement with fine aggregates analysed for its ...
In recent days there were also been many attempts to use Fly Ash, an industrial by product as partial replacement for cement to have higher workability, long term strength and to make the concrete more economically available. This present work is an attempt to use Quarry Dust as partial replacement for Sand in concrete.
2020-6-30 Corpus ID: 212579661. Partial Replacement of Sand with Quarry Dust in Concrete @inproceedings{Sukesh2013PartialRO, title={Partial Replacement of Sand with Quarry Dust in Concrete}, author={Chandana Sukesh and Katakam Bala Krishna and Pasupulety Sai Teja and Sriganesh K. Rao}, year={2013} }
2017-12-30 Utilization of Copper Slag in M-Sand as Partial Replacement of Fine Aggregate Prasanna Kumar C¹, Dr. Shashishankar², Raghavendra3 1Associate Professor and Head, DBIT, Bengaluru, India 2Professor and Head, AMC College of Engineering, Bengaluru, India Abstract: In India, there is a great demand of aggregates, mainly
Eleven concrete mixes tested with plastic as partial replacement for sand. • Target compressive strength of 54 MPa to replicate structural concrete. • Control of particle size distribution minimises change in compressive strength. • PET fragments graded as sand can be used at a replacement ratio of 10%. •
2016-11-17 partial replacement for natural river sand in order to overcome the lack of that. Hence the coir fiber can be used in construction and can reduce environmental waste by proper utilization. Also the use of coir fiber is cost effective and eco friendly. Key Words- concrete, coir
2017-4-7 Effect of replacement of River sand by M -sand in high strength concrete Mani kandhan.K.U 1, Sathya kumar.N 2, Sakthivel.R 3 1,2,3 Department of civil engineering, Bannari amman institute of technology Abstract ² During the past few decades C ommon River san d has become expe nsive due to excessive cost of transport from natural sources. ...
Partial Replacement of Sand by Quarry Dust in Concrete Sumit L. Chauhan, Raju A.Bondre Assistant Professor P. I. G. C. E. Nagpur . Abstract- The paper describe the role of quarry dust In the construction of buildings and other structures to eliminate the demand of natural sand by using quarry waste to replace the use of natural sand.
2017-4-10 replacement (10%, 20%, 30%, 40%, and 50%) of sand. Out of these 5 replacement levels best 3 were choose by trial works. The concrete was tested for slump test, compression test, flexural test, split tensile test for 7 28 days and acid attack test for 7 days. Key Words: foundry sand, ordinary Portland cement,
2018-10-31 optimize partial replacement of fine aggregate. From the result of experiments, it is found that 50% of M-sand can be replaced for fine aggregate to attain both self-compatibility and strength for concrete applications. Key words: partial replacement, m-sand, concrete elements. Cite this Article: Sabarish K V, Pratheeba Paul, M. Mohammed Aslam ...
Partial Replacement of Cement With Marble Powder in Concrete. Concrete Mix Design The concrete used in this research work was made using Binder, Sand and Gravel. The concrete mix proportion was 124 by weight. Test specimens Test specimens consisting of 150150150 mm cubes for Compressive strength, 150mm dia,
2015-12-17 Partial Replacement of M-Sand on Concrete by Self Curing and Standard Curing Method N.R.Monika1, S.Sarankokila2 Assistant Professor, Department of Civil Engineering, Nandha Engineering College, Erode, Tamilnadu, India1 Assistant Professor, Department of Civil Engineering, Nandha Engineering College, Erode, Tamilnadu, India2
2018-12-29 The optimum replacement possible for fine aggregate and cement with quartz and grog is 5%. 2. Compressive strength of concrete with optimum replacement at 7 days and 28 days of water curing is 26.14N/mm2 and 43.61 N/mm2. 3. Compressive strength of concrete with replacement of Msand by 5% quartz and 5% grog at 7 days and 28
2020-4-19 construction industry for partial or full replacement for fine and coarse aggregates. The composition of World Cement Consumption in the year 2010 is 3,313 Million Metric Tons. Among that 7.0% in India, 57.7% in China, 9.4% in Developed Countries, 25.9% in Other Emerging. The composition of Coconut Production in India in the year 2009
2015-8-15 graphical) presented here with are obtained on the tests carried out on mortar prepared by partial replacement of sand by pond flyash and adopting method of volume for design of the mix. The comparative graphs for strength of different ratio are shown for curing period of 7, 28 and 96 days and compared with the standard plain mortar of ratio 1:5.
2012-12-21 Experimental Study of Partial Replacement of Fine Aggregate with Waste Material from China Clay Industries 1 A.Seeni, 2Dr.C.Selvamony, 3Dr.S.U.Kannan, 4Dr.M.S.Ravikumar 1 Research Scholar, Anna University – Chennai, Tamilnadu, India. 2, 3, 4 Professor, Department of Civil Engineering Sun College of Engineering Technology Tamilnadu, India.
Here are few: Copper slag Presently, worldwide, about 33 million tonnes of copper slag is generated annually with India contributing 6-6.5 million tonnes. Khalifa S Al Jabri of Oman in his findings published in the internationally referred journal...
Partial Replacement of Cement With Marble Powder in Concrete. Concrete Mix Design The concrete used in this research work was made using Binder, Sand and Gravel. The concrete mix proportion was 124 by weight. Test specimens Test specimens consisting of 150150150 mm cubes for Compressive strength, 150mm dia,
2017-8-7 on partial replacement of Cement by fly ash and fine aggregate by M-Sand And coconut coir for fibre reinforcement ”,Journal of Engineering , Scientific Research and Applications, Volume 2, issue 1. [6] R.S.Deotale ,A.M.Pande(2015) “ To study the behaviour
2020-1-22 Experimental Investigation of Partial Replacement of Metakaolin, Silica Fume and M-Sand based Concrete. Dakshnamoorthy. D. 1, Gunasekaran. P. 2, Vivekanananthan.C. 3, Kavitha.A. 4, Saravanan.G. 5 ... Silica fume and M-sand replacement -30%100% . V. TEST TO FIND STRENGTH: COMPRESSIVE AND TENSILE STRENGTH TEST: Concrete was made on that ...
2019-5-15 It is observed that utilisation of Msand in SIFCON is well accepted because of its strength properties. Thus Msand can be a better replacement to riversand in Slurry infiltrated fibrous concrete. 4. The inclusion of MK as a partial cement replacement material provided an excellent improvement in
Concrete Using Msand And Partial Replacement Of Cement By Coconut Shell Ash. The demand of sand has increased greatly due to the technological advancements in the construction industry. The extraction of river sand adversely affects the ecological balance of the river. Hence alternatives to sand have been used nowadays. Th. Get Price List Chat ...
2016-7-11 Improvement of Sub grade Strength by Partial Replacement of M-Sand Mr. Suvid Raj Jain K M1, Mr. Hemanth Kumar H N2, Mr. Yashas S R3, Prof. Muralidhara. H. R4 1(Civil Engineering Department, Malnad College of Engineering, Hassan, Karnataka, India) 2(Civil Engineering Department, Malnad College of Engineering, Hassan, Karnataka, India)
2015-12-17 Partial Replacement of M-Sand on Concrete by Self Curing and Standard Curing Method N.R.Monika1, S.Sarankokila2 Assistant Professor, Department of Civil Engineering, Nandha Engineering College, Erode, Tamilnadu, India1 Assistant Professor, Department of Civil Engineering, Nandha Engineering College, Erode, Tamilnadu, India2
2018-4-13 Polyethylene wastes as partial replacement of M-sand is very strong and stiffness.The Maximum Compressive Strength of the Brick Specimen is 13.8 N/sq.mm.The Minimum Water Absorption of the Brick Specimen is 6.62 %.When the Percentage of Polyethylene is increases 15 %, the Strength will reduced and increasing the Moisture Content.
2020-7-7 Instead of disposing them in landfills, it can be best utilized as partial replacement to sand. In crusher dust, the particles (% finer than 150 microns) are generally high, a major concern limiting its percentage replacement to minimum with sand in a concrete mix. It can be replaced to the amount 25%. Its Availability is not a concern.
Here are few: Copper slag Presently, worldwide, about 33 million tonnes of copper slag is generated annually with India contributing 6-6.5 million tonnes. Khalifa S Al Jabri of Oman in his findings published in the internationally referred journal...
2014-5-26 Concrete made with limestone filler as partial replacement of cement in concrete can attain lime stone filler up to 20% without adversely effecting concrete strength 1. Concrete using . A Jayaraman /Int.J. ChemTech Res.2014,6(2),pp 948-954. 949 various combinations of lateritic sand and lime stone filler as complete replacement for conventional ...
Concrete Using Msand And Partial Replacement Of Cement By Coconut Shell Ash. The demand of sand has increased greatly due to the technological advancements in the construction industry. The extraction of river sand adversely affects the ecological balance of the river. Hence alternatives to sand have been used nowadays. Th. Get Price List Chat ...
2017-2-8 Laterite Fines as a Partial Replacement for Sand in the Production of Sandcrete Bricks”. ISSN 2250-2459, ISO 9001:2008 Certified Journal, Volume 4, Issue 10 [2] A.Jayaraman , 2013). “Experimental Study on Partial Replacement of Natural Sand with M- Sand and Cement with Lime Stone Powder”.
wage and quarry dust, Msand is an economic alternative to the river sand. In this investigations Metakaolin, as partial cement replacement and Quarry dust, Msand as partial fine aggregates replacement. A total of 15 specimens were considered and there reinforcement ratios are uniform were fabried and tested. Read more
2013-7-17 The partial replacement of cement with silica fume reduces the content of cement used in the construction industry, which protects the ecosystem with a small percentage in the reduction of green house gases. The optimum silica fume replacement percentage for obtaining maximum 28- days strength of concrete ranged from 10 to 20 % 5. Silica fume ...
Replacement of River Sand by M Sand Concrete. Dr. M. Kannan. HOD CIVIL-PITS. Paul Imbrish. Dept of CIVIL-PITS. Fantin Jesanth. A. Dept of CIVIL-PITS. Abstract:- Manufactured sand is a term used for aggregate material s less than 4.75mm and which are processed for from crushed rock or gravel. due to booming of construction activities in our country, natural sand resources are increasingly ...
2017-12-13 partial replacement and in some cases replacing fully with river sand in concrete will lead to further increase in utilisation of alternate materials keeping the environment away from the hazards. Concrete is a mixture of cement, fine aggregate, coarse aggregate and water whereas River Sand is ...
Fly ash has similar properties as CEMENT , it's going to do its work no matter what we think it should be doing. The surface area of fly ash is higher than Fine Aggregate. It requires more cement to coat the extra area due to higher addition of fl...
2020-7-7 Instead of disposing them in landfills, it can be best utilized as partial replacement to sand. In crusher dust, the particles (% finer than 150 microns) are generally high, a major concern limiting its percentage replacement to minimum with sand in a concrete mix. It can be replaced to the amount 25%. Its Availability is not a concern.
2019-7-1 1. It is observed that utilisation of Msand in SIFCON is well accepted because of its strength properties. 2. There is a steady increase in the strength of the cubes and cylinders when river sand gets replaced by Msand. 3. Thus Msand can be a better replacement to river sand in Slurry infiltrated fibrous concrete. REFERENCES . 1.